Mitsubishi Electronics MELSEC-F Home Theater Server User Manual


 
K-25
4 Programming
4.7 Error Status
FX
3G
/FX
3U
/FX
3UC
PLC User's Manual - Analog Control Edition
FX3U-4AD-PNK-ADP (4-channel Resistance Thermometer Data Input)
K
FX
3U
-4AD-PNK
-ADP
L
FX
3U
-4AD-TC
-ADP
M
PID Instruction
(FNC 88)
3. Program Example 2 (For FX3U, FX3UC Series PLC)
Y000
D8268.0
Y001
D8268.1
Y002
D8268.2
Y003
D8268.3
Y004
D8268.4
EEPROM error in 1st adapter
Y005
D8268.5
Y006
D8268.6
Y007
D8268.7
Averaging time setting error in 1st
adapter
PNK-ADP hardware error in 1st
adapter
PNK-ADP communication data error
in the 1st adapter
The temperature measurement data
of channel 1 is outside the specified
range, or disconnection is detected.
The temperature measurement data
of channel 2 is outside the specified
range, or disconnection is detected.
The temperature measurement data
of channel 3 is outside the specified
range, or disconnection is detected.
The temperature measurement data
of channel 4 is outside the specified
range, or disconnection is detected.