Upgrading an existing S8300A to R3.1 using the Web pages
244 Installing and Upgrading the Avaya G700 Media Gateway and Avaya S8300 Media Server
Note:
Note: Be sure to reset alarm origination after the upgrade.
3. Type almenable (without any options) to verify the alarm origination status.
You should see:
incoming: enable
Dial Out Alarm Origination: neither
SNMP Alarm Origination: n
Getting IA770 data and stopping IA770
(if IA770 is being used)
Skip to Backing up system files on page 247 if IA770 is not being used.
If IA770 is being used, you need to collect data, leave a test message, and shut down IA770
before backing up the files.
Creating an IA770 test message
To test IA770 after the migration
1. Write down the number of a test voice mailbox, or create one if none exists.
2. Write down the number of the IA770 hunt group.
3. Leave a message on the test mailbox that will be retrieved after the migration.
Determining whether optional languages are needed
To determine the system language
1. On the Maintenance Web Interface, under Miscellaneous select Messaging
Administration.
2. Select Global Administration then Messaging Administration.
3. Enter the craft password.
4. At the command prompt, enter display system-parameters features.
The System-Parameters Features screen displays.
5. Go to page 3.