Avaya S8300 Home Theater Server User Manual


 
DS1/T1 CPE loopback jack
Issue 9.1 June 2006 423
Testing the integrity of data sent over the loop
Now perform the second part of the test, checking for data errors.
Note:
Note: The loss of signal (LOS) alarm (demand test #138) is not processed during this
test while the 3-in-24 pattern is active.
To test the integrity of data sent over the loop
1. At the SAT, type clear meas ds1 loop XXXVS to zero out the bit-error counter.
where XXX is the administered number of the G700 or G350 (for example, 002), and VS is
the slot number on the G700 or G350 of the Media Module (for example, V3).
2. Type clear meas ds1 log XXXVS to zero out the performance measurement counter.
3. Type clear meas ds1 esf XXXVS to zero out the ESF error count.
4. Type list meas ds1 sum XXXVS to display the bit error count.
5. Step through Table 28: DS1 Troubleshooting
to troubleshoot.
Table 28: DS1 Troubleshooting
Condition Solution
The value of the
Test: cpe-loopback-jack field is
Pattern 3-in-24
The loopback jack test is active.
The value of the Synchronized field is N Retry the test 5 times.
The value of the Synchronized field
remains N after 5 tries.
Excessive bit errors are likely. Check for
intermittent connections or broken wires
in an SPE receive or transmit pair, and
repair as necessary. Then repeat Step 1.
The value of the Bit-error count field is
non-zero
Repeat Step 1 several times.
The value of the Synchronized field is Y The DS1 circuit pack has synchronized to
the looped 3-in-24 pattern and is counting
bit errors in the pattern.
1 of 2