3-6 Diagnosis function
< Spindle drive unit >
Drive unit has a function to D/A output each control data. The spindle adjustment data required to set the
spindle parameters matching the machine can be D/A output. The data can be measured with a high-speed
waveform recorder or oscilloscope, etc.
(1) D/A output specifications
When the output data is 0, the offset voltage is 2.5V. If there is an offset voltage, adjust the zero level
position in the measuring instrument side.
Item Explanation
No. of channels 2ch
Output cycle 0.8ms (min. value)
Output precision 12bit
Output voltage range 0V to 2.5V (zero) to +5V
Output magnification setting -32768 to 32767 (1/100-fold)
Output pin (CN9 connector) MO1 = Pin 9, MO2 = Pin 19, LG = Pin 1,11




















MDS-D/DH-SP
CN9 connector
Pin Pin
Name
Name
LGLG
M01
M02
+2.5 [V]
0 [V]
Speed FB
Current FB
+2.5 [V]
0 [V]
+5 [V]
+5 [V]
Scroll
Memory
Example of D/A output waveform