7 - 21
MDS-D/DH Series Specifications Manual
7-3 Selection of the power supply unit
< MDS-DH Series >
(Example 1)
The power supply unit satisfying the total of the rate output and the maximum momentary output is
MDS-DH-CV-300.
Required power supply capacity (kVA) = (29.35 / 30) x 43 = 42.0 (kVA)
(Example 2)
The power supply unit satisfying the total of the rate output and the maximum momentary output is
MDS-DH-CV-370.
Required power supply capacity (kVA) = (26.2 / 30) x 43 = 37.6 (kVA)
(Example 3)
The power supply unit satisfying the total of the rate output and the maximum momentary output is
MDS-DH-CV-370.
Required power supply capacity (kVA) = (21.75 / 30) x 43 = 31.2 (kVA)
Axis name Motor Drive unit Rated output Maximum momentary output
X-axis HF-H354 (MDS-DH-V2-8080) 3.5kW 18kW
Y-axis HF-H354 (MDS-DH-V2-8080) 3.5kW 18kW
Z-axis HF-H354 (MDS-DH-V1-80) 3.5kW 18kW
Spindle Spindle motor 22kW
MDS-DH-SP-160
(Output 22kW)
22kW 26.4kW
Total
0.7×(3.5×3)+22
=29.35kW
<31kW(DH-CV-300)
(18×3)+26.4
=80.4kW
<92kW(DH-CV-300)
Axis name Motor Drive unit Rated output Maximum momentary output
X1-axis HF-H453 (MDS-DH-V2-8080) 4.5kW 22kW
X2-axis HF-H453 (MDS-DH-V2-8080) 4.5kW 22kW
Y-axis HF-H354 (MDS-DH-V2-8080) 3.5kW 18kW
Z-axis HF-H354 (MDS-DH-V2-8080) 3.5kW 18kW
Spindle Spindle motor 15kW
MDS-DH-SP-100
(Output coefficient 1.0)
15kW 18kW
Total
0.7×(4.5×2+3.5×2)+15
=26.2kW
<31kW(DH-CV-300)
22×2+18×2+18
=98.0kW
<101kW(DH-CV-370)
Axis name Motor Drive unit Rated output Maximum momentary output
X-axis HF-H354 MDS-DH-V1-160 3.5kW 18kW
Y-axis HF-H204 MDS-DH-V2-8080 2.0kW 8kW
Z-axis HF-H204 MDS-DH-V2-8080 2.0kW 8kW
Spindle
Spindle motor 15kW
(High-torque motor)
MDS-DH-SP-320
(Output coefficient 1.1)
16.5kW 18kW
Total
0.7×(3.5+2.0×2)+16.5
=21.75kW
<31kW(DH-CV-300)
18+8×2+18
=52kW
<60kW(DH-CV-185)