Appendix 4 - 11
MDS-D/DH Series Specifications Manual
Appendix 4-6 EMC countermeasure parts
■ Example of using MX13 Series
This is a noise filter with the same dimensions as the drive unit depth (200mm) and height (380mm).
This unit can be laid out easily in the device by arraigning it in a row with the servo unit.
As with the servo unit, the terminals are arranged on the front enabling ideal wire lead-out.
Refer to the following figure for details.
[Unit:mm]
■ Example of noise terminal voltage attenuation
■ Output derating
200
380
Noise filter
(MX13 Series)
Servo unit
Wire to 3-phase power supply
Noise filter input terminal
Noise filter output terminal
Servo input terminal
Wire from noise filter to servo
Noise terminal voltage
[dBuV]
Frequency [MHz]
Frequency [MHz]
EMI data for independent control panel
(with six-axis servo unit mounted)
EMI data for control panel + noise filter (MX13030)
Noise terminal voltage
[dBuV]
Ambient temperature Ta (Υ)
Current (%)