Mitsumi electronic IB-1500875(ENG)-E Universal Remote User Manual


 
Appendix 4 - 15
MDS-D/DH Series Specifications Manual
Appendix 4-6 EMC countermeasure parts
Appendix 4-6-4 Surge protector
Insert a surge protector in the power input section to prevent damage to the control panel or power supply unit,
etc. caused by the surge (lightning or sparks, etc.) applied on the AC power line.
Use a surge protector that satisfies the following electrical specifications.
< Surge protector for 200V >
200V R•A•V-BYZ Series (for protection between lines)
(Note) Refer to the manufacturer's catalog for details on the surge protector's characteristics and
specifications.
200V R•A•V-BXZ Series (for protection between line and earth)
(Note) Refer to the manufacturer's catalog for details on the surge protector's characteristics and
specifications.
Part name
Circuit
voltage
50/60Hz
Maximum
tolerable
circuit
voltage
Clamp
voltage
Surge
withstand
level
8/20 µs
Surge
withstand
voltage
1.2/50 µs
Electrostatic
capacity
Service
temperature
RAV-781BYZ-2 3AC 250V 300V 783V±10% 2500A 20kV 75pF -20 to 70°C
Part name
Circuit
voltage
50/60Hz
Maximum
tolerable
circuit
voltage
Clamp
voltage
Surge
withstand
level
8/20 µs
Surge
withstand
voltage
1.2/50 µs
Electrostatic
capacity
Service
temperature
RAV-781BXZ-4 3AC 250V 300V 1700V±10% 2500A 2kV 75pF -20 to 70°C
2
8
.
5
r
1
5
.
5
r
1
1
1
r
1
2
8
r
1
2
0
0
+30
-0
41r1
4
.
5
r
0
.
5
UL -1015 AWG16
Outline dimension drawings
Circuit diagram
[Unit: mm]
(1)Black
(2)Black
(3)Black
U
UL-1015 AWG16
41r1
4.5r0.5
28.5r128r1
5.5r1
11r1
200
+30
-0
Outline dimension drawings
Circuit diagram
(1)Black
(2)Black
(3)Black
Green
[Unit:mm]