MITSUBISHI CNC
1 - 12
1-2-6 Power supply unit type
(1) 200V series
< MDS-D Series >
(2) 400V series
< MDS-DH Series >
MITSUBISHI
TYPE
SERVO DRIVE UNIT
MDS-D-CV-370
POWER 37kW
INPUT 164A 3PH 200/200-230V 50/60Hz
0.2A 1PH 200/200V -230V 50/60Hz
OUTPUT 121A DC270-311V
EN50178 MANUAL #IB-1500010
S/W BND5xxW000A0 H/W VER. *
SERIAL# HVA3EG1796L DATE 04/
0
MITSUBISHI ELECTRIC CORPORATION JAPAN
* H V A 3 E G 1 7 9 6 L M *
Type
Input/output conditions
Software No.
Output
Applicable standard
Serial No.
Manual No.
Rating nameplate
(1) Type
MDS - D-
Rated output Unit width
CV-37 3.7kW S-N12-AC200V NF63-CW3P-20A
CV -75 7.5kW NF63-CW3P-40A
CV-110 11.0kW D-AL-11K NF63-CW3P-50A
CV-185 18.5kW D-AL-18.5K S-N65-AC200V NF125-CW3P-100A
CV-300 30.0kW D-AL-30K S-N80-AC200V NF250-CW3P-125A
CV-370 37.0kW D-AL-37K NF250-CW3P-175A
CV-450 45.0kW D-AL-45K NF250-CW3P-200A
CV-550 55.0kW 300mm wide (Note 2) D-AL-55K S-N180-AC200V NF250-CW3P-225A
(Note 1) This is an optional part, and must be prepared by the user.
(Note 2) When connecting with a large capacity drive unit, DC connection bar is required.
Always install a large capacity drive unit in the left side of power supply unit, and connect with DC connection bar.
Power supply unit
Compatible AC reactor
Compatible contactor
(Mitsubishi)
(Note 1)
Compatible
circuit protector
(Mitsubishi)
(Note 1)
S-N25-AC200V
S- N150- A C200V
60mm wide
90mm wide
150mm wide
(Note 2)
D- AL- 7.5K
MDS-D- (1)
(1) Type
MDS - DH-
Rated output Unit width
CV-37 3.7kW NF63-CW3P-10A
CV-75 7.5kW NF63-CW3P-20A
CV-110 11.0kW DH-AL-11K S-N21-AC400V NF63-CW3P-30A
CV-185 18.5kW DH-AL-18.5K S-N25-AC400V NF63-CW3P-40A
CV-300 30.0kW DH-AL-30K S-N50-AC400V NF125-CW3P-75A
CV-370 37.0kW DH-AL-37K NF125-CW3P-100A
CV-450 45.0kW DH-AL-45K NF125-CW3P-100A
CV-550 55.0kW DH-AL-55K S-N80-AC400V NF250-CW3P-125A
CV-750 75.0kW DH-AL-75K S-N150-AC400V NF250-CW3P-200A
(Note 1) This is an optional part, and must be prepared by the user.
(Note 2) When connecting with a large capacity drive unit, DC connection bar is required.Always
install a large capacity drive unit in the left side of power supply unit, and connect with DC connection bar.
90mm w ide
Compat ibl
e
circuit protector
(Mitsubishi)
(Note 1)
300mm wide
(Note 2)
Pow er supply unit
Compatible AC reactor
Compatible contactor
(Mitsubishi)
(Note 1)
S-N12-AC400V
S-N65-AC400V
DH-AL-7.5K
150mm wide
(Note 2)
MDS-DH- (1)