Mitsumi electronic IB-1500875(ENG)-E Universal Remote User Manual


 
5 - 57
MDS-D/DH Series Specifications Manual
5-5 Cables and connectors
5-5-3 Optical communication cable specifications
(1) Specifications
(Note1) This temperature range for use is the value for optical cable (cord) only. Temperature condition for
the connector is the same as that for drive unit.
(Note2) Do not see directly the light generated from CN1A/CN1B connector of drive unit or the end of cable.
When the light gets into eye, you may feel something is wrong for eye.
(The light source of optical communication corresponds to class1 defined in JISC6802 or
IEC60825-1.)
Cable model G396-LM G380-LM
Specification application For wiring inside panel
For wiring outside panel
For long distance wiring
Cable length 0.3, 0.5, 1.0, 2.0, 3.0, 5.0m 5.0, 10, 12, 15, 20, 25, 30m
Optical
communication
cable
Minimum bend
radius
25mm
Enforced covering cable: 50mm
cord: 30mm
Tension strength 140N
980N
(Enforced covering cable)
Temperature
range for use
(Note1)
-40 to 85°C -20 to 70°C
Ambient
Indoors (no direct sunlight)
No solvent or oil
Cable
appearance
[mm]
Connector
appearance
[mm]
2.2
±
0.07
4.4
±
0.1
7.6
±
0.5
4.4
±
0.4
2.2
±
0.2
(13.4)
(15)
(6.7)
(
20.9
)
(
2.3
)
(
1.7
)
8
+0
37.65
Protection tube
22.7
8.5 20.3