5 - 5
MDS-D/DH Series Specifications Manual
5-1 Servo options
< Speed command synchronization control system configuration >
1) SIN wave signal output scale
< When using MDS-D/DH-V2 >
For the FB signal of the linear scale, the SIN wave signal is converted to Mitsubishi serial signal
with the detector conversion unit (MDS-B-HR-11), and that signal is divided to each axis control
inside 2-axis drive unit.
<When using two units of MDS-D/DH-V1>
For the FB signal of the linear scale, the SIN wave signal is converted to Mitsubishi serial signal
with the detector conversion unit (MDS-B-HR-12), and that signal is divided to each drive unit.
CON4
CON3
CON2
CON1
MDS-B-HR-11
MDS-D/DH-V2
Linear scale
( SIN wave signal output )
Detector conversion unit
Secondary axis
Primary axis
%10
%10
%10
%10
MDS-B-HR-12
MDS-D/DH-V1 MDS-D/DH-V1
Linear scale
( SIN wave signal outpu )
Detector conversion unit
Secondary axis
Primary axis
(Secondary axis)
Primary axis)