5 - 2
5 Dedicated Options
MITSUBISHI CNC
5-1 Servo options
The option units are required depending on the servo system configuration. Check the option units to be required
referring the following items.
(1) System establishment in the full closed loop control
Refer to the table below to confirm the interface unit (I/F) and battery option required for the full closed loop
control.
(a) Full closed loop control for linear axis
(Note) When using the distance-coded reference scale, it is recommended to use with distance-coded
reference check function. In this case, the battery option is required.
Machine side detector to be used
Detector signal
output
Interface unit
Drive unit
input signal
Battery
option
Remarks
Incre-
mental
detector
Rectangular
wave signal
output
SR74, SR84
(MAGNESCALE)
Rectangular wave
signal
-
Rectangular
wave signal
-
Various scale
Rectangular wave
signal
-
Rectangular
wave signal
-
SIN wave
signal
output
LS187, LS487
(HEIDENHAIN)
SIN wave signal
IBV series
(HEIDENHAIN)
Rectangular
wave signal
-
EIB series
(HEIDENHAIN)
Mitsubishi
serial signal
-
LS187C, LS487C
(HEIDENHAIN)
SIN wave signal
MDS-B-HR-11(P)
(MITSUBISHI ELECTRIC)
Mitsubishi
serial signal
(Required)
Note
Distance-coded
reference
scale
Various scale SIN wave signal
MDS-B-HR-11(P)
(MITSUBISHI ELECTRIC)
Mitsubishi
serial signal
(Required)
Note
Distance-coded
reference
scale is also
available
Mitsubishi
serial signal
output
SR75, SR85
(MAGNESCALE)
Mitsubishi serial
signal
-
Mitsubishi
serial signal
-
Abso-
lute
position
detector
Mitsubishi
serial signal
output
OSA105ET2,
OSA166ET2N
(MITSUBISHI)
Mitsubishi serial
signal
-
Mitsubishi
serial signal
Required
Ball screw end
detector
SR77, SR87
(MAGNESCALE)
Mitsubishi serial
signal
-
Mitsubishi
serial signal
Not required
LC193M, LC493M
(HEIDENHAIN)
Mitsubishi serial
signal
-
Mitsubishi
serial signal
Not required
AT343, AT543, AT545
(Mitutoyo)
Mitsubishi serial
signal
-
Mitsubishi
serial signal
Not required
SAM Series
(FAGOR)
Mitsubishi serial
signal
-
Mitsubishi
serial signal
Not required
SVAM Series
(FAGOR)
Mitsubishi serial
signal
-
Mitsubishi
serial signal
Not required
GAM Series
(FAGOR)
Mitsubishi serial
signal
-
Mitsubishi
serial signal
Not required
LAM Series
(FAGOR)
Mitsubishi serial
signal
-
Mitsubishi
serial signal
Not required
SIN wave
signal
output
MPS Series
(MME Corp.)
SIN wave signal
ADB-20J60
(MME Corp.)
Mitsubishi
serial signal
Required