7 - 16
7 Selection
MITSUBISHI CNC
(2) Calculation of spindle maximum momentary output
The spindle maximum momentary output is calculated from the following expression.
Spindle maximum momentary output
=MAX (short-time rated output x 1.2, output at acceleration/deceleration x 1.2)
(Note) For the spindle rated output, use the larger one of "short-time rated output x 1.2" and "output at
acceleration/deceleration x 1.2".
7-3-2 Calculation of servo motor output
(1) Selection with rated output
(2) Selection with maximum momentary output
For the rated output and maximum momentary output of the servo motor, use the value corresponding to the
servo motor in the table 3.
Table 3. Data for servo motor output selection
< 200V series >
< 400V series >
(Note) The maximum momentary output in this table is reference data for selecting the power supply
unit and is not data which guarantees the maximum output.
Motor HF 75 105 54 104 154 224 204 354
Rated output (kW) 0.75 1.0 0.5 1.0 1.5 2.2 2.0 3.5
Maximum momentary output
(kW)
2.6 3.6 2.3 5.0 9.0 12.3 8.0 18.0
Motor HP 123 223 303 453 703 903 142 302
Rated output (kW) 1.2 2.2 3.0 4.5 7.0 9.0 1.4 3.0
Maximum momentary output
(kW)
4.0 7.5 12.0 22.0 28.0 41.0 3.8 7.4
Motor HP 54 104 154 224 204 354 454 704 903 1103
Rated output (kW) 0.5 1.0 1.5 2.2 2.0 3.5 4.5 7.0 9.0 11.0
Maximum momentary output
(kW)
2.3 4.3 8.0 11.0 11.0 15.0 21.0 27.0 33.0 50.0
Motor HF-KP 23 43 73
Rated output (kW) 0.2 0.4 0.75
Maximum momentary output
(kW)
0.72 1.72 2.85
Motor HF-H 75 105 54 104 154 204 354 453 703 903
Rated output (kW) 0.75 1.0 0.5 1.0 1.5 2.0 3.5 4.5 7.0 9.0
Maximum momentary output
(kW)
2.6 3.6 2.3 5.0 9.0 8.0 18.0 22.0 28.0 41.0
Motor HP-H 54 104 154 224 204 354 454 704 903 1103
Rated output (kW) 0.5 1.0 1.5 2.2 2.0 3.5 4.5 7.0 9.0 11.0
Maximum momentary output
(kW)
2.3 4.3 8.0 11.0 11.0 15.0 21.0 27.0 33.0 50.0
Motor HC-H 1502S-S10
Rated output (kW) 15.0
Maximum momentary output
(kW)
59.0