Mitsumi electronic IB-1500875(ENG)-E Universal Remote User Manual


 
MDS-D/DH Series Specifications Manual
2-4 Drive unit
2 - 53
2-4-3 Spindle drive unit
(1) 200V series
< MDS-D Series >
1-axis spindle drive unit MDS-D-SP Series
Spindle drive unit type
MDS-D-SP-
20 40 80 160 200 240 320 400 640
Nominal maximum current (peak) [A] 20 40 80 160 200 240 320 400 640
Output
Rated voltage [V] 155AC
Rated current [A] 4.5 10 18 37 63 79 130 174 200
Input
Rated voltage [V] 270 to 311DC
Rated current [A] 7 13 20 41 76 95 140 150 210
Control
power
Voltage [V] 200AC (50Hz) / 200 to 230AC (60Hz) Tolerable fluctuation : between +10% and -15%
Frequency [Hz] 50/60 Tolerable fluctuation : between +3% and -3%
Maximum current [A] 0.2
Maximum rush current [A] 30
Maximum rush conductivity
time [ms]
69
Earth leakage current [mA] 6 (Max. 15)
Control method Sine wave PWM control method
Braking Regenerative braking
External analog output 0 to +5V, 2ch (data for various adjustments)
Degree of protection IP20 ([over all] / IP00 [Terminal block TE1])
Cooling method Forced wind cooling
Mass [kg] 3.8 4.5 5.8 6.5 7.5 16.5
Heat radiated at continuous rated output [W] 55 94 158 290 481 620 806 1045 1427
Noise Less than 55dB
Unit outline dimension drawing A1 A1 A1 B1 C1 D1 D2 E1 F1
2-axis spindle drive unit MDS-D-SP Series
Spindle drive unit type
MDS-D-SP-
2020 4020 4040S 4040 8040 16080S 8080 16080
Nominal maximum current (peak) [A] 20/20 40/20 40/40 40/40 80/40 160/80 80/80 160/80
Output
Rated voltage [V] AC155
Rated current [A] 4.5 / 4.5 10 / 4.5 10 / 10 10 / 10 18 / 10 37 / 18 18 / 18 37 / 18
Input
Rated voltage [V] 270 to 311DC
Rated current [A] 14(7 / 7) 20(13 / 7) 26(13 / 13) 26(13 / 13) 33(20 / 13) 61(41 / 20) 40(20 / 20) 61(41 / 20)
Control
power
Voltage [V] 200AC (50Hz) / 200 to 230AC (60Hz) Tolerable fluctuation : between +10% and -15%
Frequency [Hz] 50/60 Tolerable fluctuation : between +3% and -3%
Maximum current [A] 0.2
Maximum rush current [A] 30
Maximum rush conductiv-
ity time [ms]
6
Earth leakage current [mA] 6 (Max. 15)
Control method Sine wave PWM control method
Braking Regenerative braking
External analog output 0 to +5V, 2ch (data for various adjustments)
Degree of protection IP20 ([over all] / IP00 [Terminal block TE1])
Cooling method Forced wind cooling
Mass [kg] 4.5 4.5 4.5 6.5 6.5 5.2 6.5 6.5
Heat radiated at continuous rated output
[W]
90 129 168 168 232 428 298 428
Noise Less than 55dB
Unit outline dimension drawing A1 A1 A1 B1 B1 B1 C1 C1