TECHNICAL SPECIFICATIONS
General Specifications
350-8697 DGy Model 201 User Guide 131
. . . . .
CONTROL
. . . . . . . . .
SPECIFICATIONS
The table below lists DGy 201 control specifications:
Table A-8. Control Specifications
Parameter Specification
Control Protocol DGy 201 Control is accomplished by use of the DGy 201 ASCII
based command set. This command set may be used with any of
the control ports listed below. (see the “
Command Set List” section
in Chapter 6 for details).
Ethernet 10/100 BASE-T ethernet port.
• Supports control of the full set of DGy 201 commands
over a network connection using a Telnet server/client
architecture.
• Internal DGy 201 web server provides the Web Control
Panel (WCP) a graphical user interface used with a
standard web browser.
• The DGy 201 Ethernet port connector type is a standard
RJ45 modular connector (see the “
Ethernet Connector”
on page 136)
RS-232 Port DGy 201 commands can be sent through the RS-232 port to
control the system.
• The RS-232 port transfers commands using the
asynchronous serial protocol at 115200, 57600, 38400,
19200 or 9600 baud.
• The port is configured as DCE and can handle full duplex
transfer.
• Support for hardware and software handshaking is
provided.
• The DGy 201 RS-232 port connector type is a 9-pin sub
miniature D connector (see the “
RS-232 Connector”
section on page 127 for details).