TECHNICAL SPECIFICATIONS
General Specifications
350-8697 DGy Model 201 User Guide 132
. . . . .
. . . . . . . . .
IRIG TIME CODE
The table below lists specifications for the optional IRIG-B timecode
interface. The interface is designed in accordance with the requirements
of the Range Commanders Council (RCC) document 200-04 (Defense
Technical Information Center).
Table A-9. IRIG Timecode specification
Parameter Specification
IRIG Type IRIG-B (Time frame of 1 sec, BCD time of year, SBS)
Format B123
Interface DCLS (dc level shift code)
1 kHz amplitude modulated.
Signal Level 2 -3 V peak to peak (10v p-p maximum)
Connector Type BNC female (looping input, bridging impedance)
POWER AND
PHYSICAL
. . . . . . . . .
SPECIFICATIONS
The table below lists DGy 201 power and physical specifications:
Table A-10. Power and Physical Specifications
Parameter Specification
Input Voltage 100-240 VAC
Frequency 50Hz - 60 Hz
Power Consumption 65 VA
Power Factor Correction Compliant with EN 61000-3-2
Size 17.25"W (excluding rack mount ears) x 19.0"D x 1.75"H
Rack Mount Kit Included
Weight 14 pounds (6.4 kg)