Raritan Computer 4.3.1 Cable Box User Manual


 
114 PARAGON II USER GUIDE
Redundant Configuration
These configurations are simply more complex configurations, and might be used to ensure
redundancy; every Base Unit is configured to another, in case of individual system failure.
The procedure outlined below must be followed to ensure this configuration functions
properly:
After installation, all Paragon switches should undergo a FUNC reset to clear the
database. See Reset Unit under Paragon II Front Panel Display and Controls in
Chapter 2 for m
ore information on clearing the database. This procedure should be
performed starting from the third-tier device down to the Base Unit.
Execute the FUNC reset in the following order: UMT-3A UMT-3B UMT-2A
UMT-2B UMT-1A UMT-1B.
Whenever a third-tier Paragon switch is replaced, all of the second-tier and base-tier
Paragon switches should undergo a FUNC reset.
Whenever a second-tier Paragon switch is replaced, all of the base-tier Paragon switches
should undergo a FUNC reset.
Whenever a base-tier Paragon switch is replaced, only the new Paragon switch should
undergo a FUNC reset.
Figure 97 Redundant Configuration