22 PARAGON II USER GUIDE
If a “failed” condition is detected, make sure the Category 5e UTP cable is installed properly
and secured, or try using another CIM to see if the CIM under test has become defective.
Figure 15 Channel CIM (UKVM) Test
4. Test Stack Unit: Press the U or V button to select the corresponding Stacking Unit ID for
any connected units. If there are no Stacking Units connected, the LCD will display “None”.
If there are Stacking Units connected, the LCD should read “OK” for each unit. Press ESC
to return to normal display.
5. Stacking Support: Press the U or V button to set the Stacking Unit ID number (0 – 3 for a
P2-UMT832M or 0-1 for a P2-UMT1664M). The default is set to “0” (no Stacking Units
connected). If you wish to add Stacking Units, this number must be equal to the number of
Stacking Units connected. Press ENT to save the value or ESC to cancel and return to
normal display.
Figure 16 Stacking Support
6. Set LCD Contrast: Modifies contrast level of front panel LCD Display. Press the U or V
button to increase or decrease contrast, and press the ESC button to return to normal display.
Figure 17 Set LCD Contrast
Note: LCD contrast can also be adjusted by holding the
Y
button and pressing the
U
or
V
button at any time.
7. Re-Configure: Paragon II will automatically configure the system as computers or devices
are added or removed. However, the system administrator can use this function to scan and
re-configure the system manually. When complete, it will return to normal display.
Figure 18 Auto Configure
8. Set IP Address: As an administrator, you may change Paragon II’s IP address directly from
the front panel of the device. The Paragon II’s current IP address will be displayed, along
with a cursor. Use the Y and Z keys to move the cursor over digit-by-digit, and use the U or
V keys to change the value of that digit. Press the ENT button when the new IP address has
been set. Press the ENT button again to save changes and reboot the unit when asked to
“Save Changes?” The unit will restart with the new network address.