109
7.5.2 MII specifications
Table 29. MII AC Specification
Parameter Min Max Units Conditions
PHY mode output Setup time 10 ns
P_RXD_M_TXD,
P_RX_DV_M_TX_EN,
P_RX_ER_M_TX_ER,
↑P_RX_CLK_M_TX_CLK
PHY mode output hold time 10 ns
P_RXD_M_TXD,
P_RX_DV_M_TX_EN,
P_RX_ER_M_TX_ER,
↑P_RX_CLK_M_TX_CLK
MAC mode output Setup time 15 ns
P_RXD_M_TXD,
P_RX_DV_M_TX_EN,
P_RX_ER_M_TX_ER,
↑P_RX_CLK_M_TX_CLK
MAC mode output hold time 0 ns
P_RXD_M_TXD,
P_RX_DV_M_TX_EN,
P_RX_ER_M_TX_ER,
↑P_RX_CLK_M_TX_CLK
PHY mode Input Setup time 15 ns
P_TXD_M_RXD,
P_TX_DV_M_RX_EN,
P_TX_ER_M_RX_ER,
↑P_TX_CLK_M_RX_CLK
PHY mode Input hold time 0 ns
P_TXD_M_RXD,
P_TX_DV_M_RX_EN,
P_TX_ER_M_TX_ER,
↑P_TX_CLK_M_RX_CLK
MAC mode Input Setup time 10 ns
P_TXD_M_RXD,
P_TX_DV_M_RX_EN,
P_TX_ER_M_TX_ER,
↑P_TX_CLK_M_RX_CLK
MAC mode Input hold time 10 ns
P_TXD_M_RXD,
P_TX_DV_M_RX_EN,
P_TX_ER_M_TX_ER,
↑P_TX_CLK_M_RX_CLK