8.10 Reset specification
The HDMP-3001 reset pin (RSTB)
is an asynchronous pin that must
be active for at least 200 SONET
clock cycles (>10µs) with stable
power.
TX_CLK
TX_D[3:0], TX_EN, TX_ER
RX_D[3:0], RX_DV, RX_ER
RX_CLK
t
TX
0 ns MIN., 25 ns MAX.
t
RXS
10 ns MIN.
t
RXH
10 ns MIN.
VALID
VALID
Figure 38. MII timing as defined by IEEE 802.3
8.11 MII Timing
HDMP-3001 meets the MII timing
as defined by IEEE 802.3 as