Pelco DX8100 DVR User Manual


 
C2630M-C (7/09) 167
Configuring Advanced Video Loss-Activated Relay Output
To configure an advanced video loss-activated relay output:
1. On the DX8100 toolbar, click the Setup button . The Setup dialog box opens to the Camera page.
2. In the Setup dialog box, click Schedule button . The Schedule page is displayed.
3. Click the Configure Relays button. The Configure Relays dialog box opens.
4. Click the Video Loss tab if it is not already selected.
5. Configure each relay that is linked to an alarm:
a. Click the drop-down box to select a relay.
b. Select a relay time value from the Activation Period drop-down box.
Figure 139. Linking Relays to Video Loss
Table AO describes the available video loss-activated relay settings.
Table AO. Video Loss-Activated Relay Settings
Option Result
Disable Relay will not activate when a video loss event occurs.
Follow Event Relay will activate at the exact moment the video loss event happens.
1, 3, 5, 10, 15, and 20 Seconds Sets the amount of time the relay will remain active after the video loss event occurs.
5a
5a
5
b