104 English
RECORD SET2
INTRODUCTION SETTINGS NETWORK
CONTROL
NETWORK
OPERATION
NETWORK
SETTINGS
OTHEROPERATION
[Settings] ( indicates default setting)
*1 Multi screen display is laid out according to the settings on
P.126. Therefore, the image for the channel for which an
alarm was detected may not be displayed depending on
the settings when multi 9 screen display is selected.
Special care should be taken.
*2 Only for the DSR-5016P
8 Turn the shuttle dial clockwise.
“LAST” flashes.
9 Turn the jog dial to select the “ALARM
PRIORITY” setting and then turn the
shuttle dial clockwise.
The cursor moves to “MON.2 DISPLAY”.
[Settings] ( indicates default setting)
z After an alarm duration has ended, the display returns to
the screen prior to the alarm.
z “ALARM PRIORITY” cannot be selected when “MAIN
MON. DISPLAY” is set to “9”, “16” or “NC”.
10 Turn the shuttle dial clockwise.
“NC” flashes.
11 Turn the jog dial to select the “MON.2
DISPLAY” value and then turn the
shuttle dial clockwise.
[Settings] ( indicates default setting)
*1 Only for the DSR-5016P
12 Press the [EXIT/OSD] button.
The setting is completed and the display returns to the normal
screen.
Setting Description
FULL
When an alarm is detected, the main monitor
displays in full screen format the video on the
channel containing the alarm.
9
*1
When an alarm is detected, the main monitor
displays multi 9 screens.
16
*2
When an alarm is detected, the main monitor
displays multi 16 screens.
NC
The display on the main monitor does not change
when an alarm is detected.
Setting Description
LAST
When a number of alarms occur, the most
recent alarm video is given priority and is
displayed.
FIRST
When a number of alarms occur, only the
video for the first alarm is displayed.
However, if the duration for the first alarm
expires, video for the next alarm is
displayed.
SWITCH
When a number of alarms occur, the
display switches between the video from
the corresponding cameras, showing each
for one second.
<ALARM OPERATION SET>
ALARM RETRIGGER : ON
MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : NC
<ALARM OPERATION SET>
ALARM RETRIGGER : ON
MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : NC
Setting Description
NC
When an alarm is detected, Monitor 2 does
not change.
FULL
When an alarm is detected, the image of
the channel that received the alarm is
displayed full screen on Monitor 2.
9
When an alarm is detected, Monitor 2
appears in multi 9 screen display.
16
*1
When an alarm is detected, Monitor 2
appears in multi 16 screen display.
<ALARM OPERATION SET>
ALARM RETRIGGER : ON
MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : NC
<ALARM OPERATION SET>
ALARM RETRIGGER : ON
MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : NC
EXIT/OSD