Sanyo DSR-5009P DVR User Manual


 
ADVANCED MENU SET8
English 145
Set when cameras with remote operation capability are
connected.
To perform camera control for a SANYO camera, set
“CONTROL” in the <RS-232C/RS-485 SET> screen to RS-
485. (JP.115)
Perform the following connections and set camera control to
use in full screen display.
Connections necessary for remote operation:
z Connect coaxial control cameras to the VIDEO terminal.
z Connect the Sanyo RS-485 control camera to the RS-485
(RJ-11) terminal.
z Connect another maker’s RS485/422 control camera to the
2ND RS485/422 terminal.
z If “ADDRESS” in the <RS-232C/RS-485 SET> screen
(JP.116) is set to between “001” and “008”, camera
control settings can be performed. Camera control settings
are not available if “ADDRESS” is set to “000” or between
“009” and “127”.
1 Press the [MENU] button.
The MENU indicator lights up and the <MAIN MENU> is
displayed.
2 Turn the jog dial to select
“8.ADVANCED MENU SET” and then
turn the shuttle dial clockwise.
The <ADVANCED MENU SET> screen is displayed.
3 Turn the jog dial to select “3.CAMERA
CONTROL SET” and then turn the
shuttle dial clockwise.
The <CAMERA CONTROL SET> screen is displayed.
4 Turn the jog dial to select the camera
number corresponding to a connected
dome camera and then turn the shuttle
dial clockwise.
The “PROTOCOL” input field flashes.
On the DSR-5009P, cameras No. 01-09 are displayed.
5 Turn the jog dial to select a protocol and
then turn the shuttle dial clockwise.
The cursor moves to the next “PROTOCOL” field.
[Settings] ( indicates default setting)
z “COAX” stands for coaxial control and the video signal and
camera control signal. This requires no further wiring for
signal control.
6 Use the same procedure to set the
connection channels of other dome
cameras.
Camera control settings
MENU
<CAMERA CONTROL SET>
CH PROTOCOL ADD | CH PROTOCOL ADD
01 OFF --- | 09 OFF ---
02 OFF --- | 10 OFF ---
03 OFF --- | 11 OFF ---
04 OFF --- | 12 OFF ---
05 OFF --- | 13 OFF ---
06 OFF --- | 14 OFF ---
07 OFF --- | 15 OFF ---
08 OFF --- | 16 OFF ---
2ND RS485/422 PROTOCOL : OFF
Setting Description
OFF No protocol
SANYO COAX1 SANYO COAX
SANYO RS485 SANYO RS485
BBV COAX BBV COAX
PELCO COAX PELCO COAX
2ND RS-485/422 2ND RS-485/422
SANYO COAX2 SANYO COAX (High speed)
<CAMERA CONTROL SET>
CH PROTOCOL ADD | CH PROTOCOL ADD
01 OFF --- | 09 OFF ---
02 OFF --- | 10 OFF ---
03 OFF --- | 11 OFF ---
04 OFF --- | 12 OFF ---
05 OFF --- | 13 OFF ---
06 OFF --- | 14 OFF ---
07 OFF --- | 15 OFF ---
08 OFF --- | 16 OFF ---
2ND RS485/422 PROTOCOL : OFF
<CAMERA CONTROL SET>
CH PROTOCOL ADD | CH PROTOCOL ADD
01 SANYO COAX1 001 | 09 OFF ---
02 OFF --- | 10 OFF ---
03 OFF --- | 11 OFF ---
04 OFF --- | 12 OFF ---
05 OFF --- | 13 OFF ---
06 OFF --- | 14 OFF ---
07 OFF --- | 15 OFF ---
08 OFF --- | 16 OFF ---
2ND RS485/422 PROTOCOL : OFF
e00_l8hbd_xe_7.book Page 145 Tuesday, April 5, 2005 11:41 AM