RECORD SET2
English 85
z When only one camera is connected, recording is
performed at 25 FPS even if 50 or 100 FPS is set.
z When four cameras are connected and 100 FPS is set,
recording is performed at the recording rate close to the set
rate (100 FPS) divided by the number of cameras.
(Example: When 8 cameras are connected and the
recording rate setting is 100 FPS, the actual recording rate
is 12.5 FPS)
10 Turn the shuttle dial clockwise.
“OFF” flashes.
11 Turn the jog dial to select the “REC
PROGRAM GROUP” number and then
turn the shuttle dial clockwise.
Example: P-1
[Settings] ( indicates default setting)
12 Press the [EXIT/OSD] button.
The setting is completed and the display returns to the normal
screen.
Use the following procedure to program the camera numbers
for recording. Four programs can be set. For example,
Program No. 1 could be setup to record from cameras No. 1
through No. 4 only, whereas Program No. 2 could be setup to
record from cameras No. 3 through No. 6. In addition, these
programs can also be used for timer recording.
z Even if audio recording is set to “ON” using the <NORMAL
REC MODE SET> screen, certain settings for program
recording may make audio recording impossible. Set more
than one of the 16 channels to 1 FPS or greater to record
audio.
On the DSR-5009P, set more than one of the nine
channels.
(1) PROGRAM
Selects Program No. 1 through Program No. 4.
(2) SELECT INDIVIDUAL CAMERA RATE
Sets which of the connected cameras to record from.
Recording rates can also be set for each camera.
Example: Setting Program No. 1 to record video only from
cameras No. 1 through No. 3 at a recording rate of 5
1 Press the [MENU] button.
The MENU indicator lights up and the <MAIN MENU> is
displayed.
2 Turn the jog dial to select “2.RECORD
SET” and then turn the shuttle dial
clockwise.
The <RECORD SET> screen is displayed.
Setting Description
OFF
Video from all cameras is recorded at the
same rate.
P-1 Used when recording with Program No. 1.
P-2 Used when recording with Program No. 2.
P-3 Used when recording with Program No. 3.
P-4 Used when recording with Program No. 4.
<NORMAL REC MODE SET>
PICTURE QUALITY : ENHANCED
PICTURE QUALITY SET ->
AUDIO RECORDING : ON
REC RATE : A 12.5 FPS ( 156H)
REC PROGRAM GROUP : OFF
<NORMAL REC MODE SET>
PICTURE QUALITY : ENHANCED
PICTURE QUALITY SET ->
AUDIO RECORDING : ON
REC RATE : ***** FPS ( 0H)
REC PROGRAM GROUP : P-1
EXIT/OSD
Setting program recording
<PROGRAM REC SET>
PROGRAM : P-1
SELECT INDIVIDUAL CAMERA RATE (FPS)
01:1 02:1 03:1 04:1
05:1 06:1 07:1 08:1
09:1 10:1 11:1 12:1
13:1 14:1 15:1 16:1
NORMAL REC : 57H
(1)
(2)
MENU
e00_l8hbd_xe_7.book Page 85 Tuesday, April 5, 2005 11:41 AM