Sanyo DSR-5009P DVR User Manual


 
Specifications3
220 English
INTRODUCTION SETTINGS NETWORK
CONTROL
NETWORK
OPERATION
NETWORK
SETTINGS
OTHEROPERATION
CTL10 Alarm reset input
[No-volt contacts]
CTL11 Non rec output
[DC5V/5.7k, Active Low]
CTL12 Warning output
[DC5V/5.7k, Active Low]
CTL13 Normal recording
area disk full warning output
[DC5V/5.7k, Active Low]
CTL14 Archive area disk full
warning output terminal
[DC5V/5.7k, Active Low]
Input/output terminals Signal level Input/output circuit
0V
Open
ground
input
100ms or more
10k
100k
5V
1k
IC
74HC597
Terminal
0V
5V
Stop recording
1k
4.7k
5V
IC
BU209
Terminal
0V
5V
Warning conditions established
(HDD error, FAN error detected)
1k
4.7k
5V
IC
BU209
Terminal
0V
5V
Warning conditions established
(no space in normal recording area)
1k
4.7k
5V
IC
BU209
Terminal
0V
5V
Warning conditions established
(no space in archive area)
1k
4.7k
5V
IC
BU209
Terminal
e00_l8hbd_xe_7.book Page 220 Tuesday, April 5, 2005 11:41 AM