TECHNICAL SPECIFICATIONS
General Specifications
350-9047 v3.0.1 DGy Model 201x User’s Guide 124
. . . . .
CONTROL
. . . . . . . . .
SPECIFICATIONS
The table below lists DGy 201x control specifications:
Table A-7 Control Specifications
Parameter Specification
Control Protocol DGy 201x control is accomplished by use of the DGy 201x ASCII
based command set. This command set may be used with the serial
and Ethernet control ports listed below. (see the
Commands
section in Chapter 6 for details).
Ethernet 100/1000 Base-T Ethernet port.
• Supports control of the full set of DGy 201x commands
over a network connection using a Telnet server/client
architecture.
• Internal DGy 201x web server provides the Web Control
Panel (WCP) a graphical user interface used with a
standard web browser.
• The DGy 201x Ethernet port connector is a standard
RJ45 modular connector (see the
Ethernet Connector on
page 128).
RS-232 Port DGy 201x commands can be sent through the RS-232 port to
control the system.
• The RS-232 port transfers commands using the
asynchronous serial protocol at 115200 (default), 57600,
38400, 19200 or 9600 baud.
• The port is configured as DCE and can handle full duplex
transfer.
• Support for hardware and software handshaking is
provided.
• The DGy 201x RS-232 port connector type is a 9-pin, sub
miniature D connector (see the
RS-232 Connector section
on page 120 for details).