RGB Spectrum DGy 201x DVR User Manual


 
OPERATION
Options Window
350-9047 v3.0.1 DGy Model 201x User’s Guide 53
. . . . .
GAMMA
Use this adjustment when the replay device has a different
gamma than that of the recorded image. An example would be
between a CRT and an LCD monitor. The range is from 0.5 to 2
in increments of 0.05.
TIMING LIST
When the output Mode is set to Freerun, use the Timing List
section of the Output tab to set the output format. Select the
required format from the drop down
Timing List and click on the
Load button.
The timing parameters associated with the format selected from
the
Timing List are displayed in the Video Output Timing section
of the
Output tab. Click the Edit box to make changes to the
parameters. Modified settings may then be saved to the
Timing
List
by selecting an unused entry in the list, between 100 and
160, and clicking the
Save button. Unwanted entries to the
Timing List can be deleted by selecting an entry and clicking
Delete.
To return to the default autosync mode, set the output
Mode to
Playback.
VIDEO OUTPUT TIMING
Output timing parameters are displayed for the timing selected
from the
Timing List. These parameters may be edited checking
the
Edit box.
See Making Timing Adjustments
on page 49 for more
information on timing parameters.
SYNC TYPE
Select the synchronization parameters as required.
SCAN RATE
Set the Scan Rate parameters as required.
Note The gamma of the input image recorded to disk is
preserved. The
Gamma control does not apply to the
input image.
Important Changing timing parameters should be done by
experienced video engineers only.