RGB Spectrum DGy 201x DVR User Manual


 
TECHNICAL SPECIFICATIONS
General Specifications
350-9047 v3.0.1 DGy Model 201x User’s Guide 125
. . . . .
. . . . . . . . .
IRIG TIME CODE
The table below lists specifications for the optional IRIG-B timecode
interface. The interface is designed in accordance with the requirements
of the Range Commanders Council (RCC) document 200-04 (Defense
Technical Information Center).
POWER AND
PHYSICAL
. . . . . . . . .
SPECIFICATIONS
The table below lists DGy 201x power and physical specifications:
Table A-8 IRIG Timecode Specification
Parameter Specification
IRIG Type IRIG-B (time frame of 1 sec, BCD time of year, SBS)
Format B123
Interface DCLS (dc level shift code)
1 kHz amplitude modulated.
Signal Level 2 -3 V peak-to-peak (10 V maximum)
Connector Type BNC female (looping input, bridging impedance)
Table A-9 Power and Physical Specifications
Parameter Specification
Input Voltage 100-240 VAC
Frequency 50Hz - 60 Hz
Power Consumption 65 VA
Power Factor Correction Compliant with EN 61000-3-2
Size 17.25"W (excluding rack mount ears) x 19.0"D x 1.75"H
Rack Mount Kit Included
Weight 16 pounds (7.3 kg)