COMMUNICATIONS SETUP
Ethernet Control
350-9047 v3.0.1 DGy Model 201x User’s Guide 137
. . . . .
At this point, the Telnet window starts and DGy 201x responds
with the product name and copyright notice as shown in Figure
B-6.
Figure B-6 Telnet Connected
6. To change the current IP address, type IPADDR followed by DGy
201x’s new IP Address (as provided by the network
administrator).
S Example: If the new IP address is 192.168.1.190, type:
IPADDR 192.168.1.190
... and press ENTER
DGy 201x responds with the following message:‘
The system must be restarted for your changes to
take effect.
Do you want to restart the system (y/n)?
Type y to accept the new address, or n to retain the current
address.
7. If y is pressed in the step above, the DGy 201x reboots and the
Telnet connection is lost. Repeat steps 2 through 4 to establish a
new Telnet session — except in step 4, type the new IP address.
8. Confirm the new setting by typing the command IPADDR and
pressing ENTER. If the DGy 201x has accepted the command,
it will respond with the new IP address.
In addition to setting the IP address, if required set the IP subnet mask
(
IPSubNET) and gateway (IPGateWay). See page 116 for more details.
Important When the IP address is changed from the Ethernet
port, the Telnet connection and communication will be
lost. This behavior is to be expected. Restart the
Telnet session using the new IP address.