FIRMWARE UPGRADE
Manual Update Procedure
350-9047 v3.0.1 DGy Model 201x User’s Guide 146
. . . . .
7. Type the command bin and press ENTER.
8. Upload the firmware to the DGy 201x by issuing the put
command followed by the firmware file name. The file name is
case sensitive and must be entered exactly. In the example
shown in
Figure C-8 the entry is:
put FWDGY.3.08.tgz press ENTER.
9. Type ls and press ENTER to verify that the file was uploaded.
10. Type bye and press ENTER to exit ftp.
. . . . . . . . .
UPDATE FIRMWARE
11. At the prompt, begin a new Telnet session.
Figure C-9 Update Firmware Command
12. Type the ufw command and press ENTER.
13. Type y to proceed or n to terminate the process.
After about 30 seconds, the connection to the host will be lost.
. . . . . . . . .
FTP FPGA FILE
14) Re-establish the FTP connection as described in Step 4. above.
15. Enter the user name rgb.
16. Enter the password spectrum (case sensitive).
Caution Failure to enter the bin command will cause the files
to be corrupted on transfer.
Important Communications with the DGy 201x will be lost during
the installation process. This is normal and does not
indicate that there is a problem with the installation
process. This process approximately two minutes.
DO NOT turn the power off during this time.