Sony SRW-5000 VCR User Manual


 
Menu List
A-48 Appendix
Appendix
Items Relating to the Pull Down Control (A01~)
Item number Setting FunctionItem
A01 PD TIME CODE
DISPLAY
[off]
on
Sets whether or not to display the pull down time code on
the time code display area.
off: Does not display the pull down time code.
on: Displays the pull down time code.
A02 PD PRESET
FRAME MODE
[24 FRAME MODE]
30 FRAME MODE
Selects the time code to be preset. The A frame of the
pulldown sequence can be preset.
24 FRAME MODE: The 24 frames time code is preset.
30 FRAME MODE: The 30 frames time code is preset.
A03 SUPERIMPOSED
CHARACTER
[off]
on
Specifies whether or not to superimpose time data and
operating status information on the signal output from the
FORMAT CONV. OUT connector.
off: No information is superimposed.
on: Information is superimposed.
A04
PD DF/NDF
SELECT
[drop frame]
non-drop frame
auto
Selects the running mode for the pull down time code to be
preset.
drop frame: Drop frame mode
non-drop frame: Non-drop frame mode
auto: The unit switches the running mode (DF/NDF)
automatically according to the frame frequency of the
unit. When the frame frequency is 23.98 Hz, the unit
switches to the drop frame mode and switches to the
non-drop frame mode when it is 24 Hz.
A05
PD EXT SD REF
LOCK MODE
[off]
lock1
lock2
When the operating frequency is set to 23.98PsF, specifies
whether or not the pull down output signal and down-
converted output signal are synchronized with the reference
signal by the REF INPUT 2 connector.
off: The pull down output signal and down-converted output
signal are not synchronized with the reference signal by
the REF INPUT 2 connector.
lock1: The pull down output signal and down-converted
output signal are synchronized with the reference signal
by the REF INPUT 2 connector.
lock2: The pull down output signal and down-converted
output signal are synchronized with the reference signal
by the REF INPUT 2 connector. When the PB/EE mode
is selected, the amount of delay on the A frame of the
pull down output signal for the A frame of the main video
signal is fixed to 2 frames (59.94i).
Notes
•A warning message appears when the HD reference
signal and REF INPUT 2 reference signal are not input or
not synchronized.
“lock1” and “lock2” are effective only when the operation
mode of this unit is set to 23.98/24PsF.
• When editing in 23.98/24PsF mode, with this unit as the
recorder and with “lock2” selected, phase synchronization
may not be achieved within 5 seconds. In this case, select
“off”.
(Continued)