Table 15-2 Transfer Rate
Bit 3 Bit 2 Bit 1 Bit 0 Transfer Rate
CKS3 CKS2 CKS1 CKS0
Clock
φ=5 MHz φ=8 MHz φ=10 MHz φ=16 MHz
0 φ/28 179 kHz 286 kHz 357 kHz 571 kHz0
1 φ/40 125 kHz 200 kHz 250 kHz 400 kHz
0 φ/48 104 kHz 167 kHz 208 kHz 333 kHz
0
1
1 φ/64 78.1 kHz 125 kHz 156 kHz 250 kHz
0 φ/80 62.5 kHz 100 kHz 125 kHz 200 kHz0
1 φ/100 50.0 kHz 80.0 kHz 100 kHz 160 kHz
0 φ/112 44.6 kHz 71.4 kHz 89.3 kHz 143 kHz
0
1
1
1 φ/128 39.1 kHz 62.5 kHz 78.1 kHz 125 kHz
0 φ/56 89.3 kHz 143 kHz 179 kHz 286 kHz0
1 φ/80 62.5 kHz 100 kHz 125 kHz 200 kHz
0 φ/96 52.1 kHz 83.3 kHz 104 kHz 167 kHz
0
1
1 φ/128 39.1 kHz 62.5 kHz 78.1 kHz 125 kHz
0 φ/160 31.3 kHz 50.0 kHz 62.5 kHz 100 kHz0
1 φ/200 25.0 kHz 40.0 kHz 50.0 kHz 80.0 kHz
0 φ/224 22.3 kHz 35.7 kHz 44.6 kHz 71.4 kHz
1
1
1
1 φ/256 19.5 kHz 31.3 kHz 39.1 kHz 62.5 kHz
15.3.2 I
2
C Bus Control Register 2 (ICCR2)
ICCR1 is an 8-bit readable/writable register that issues start/stop conditions, manipulates the SDA
pin, monitors the SCL pin, and controls reset in I
2
C control part.
Bit Bit Name Initial Value R/W Description
7 BBSY 0 R/W Bus Busy
This bit enables to confirm whether the I
2
C bus is occupied
or released and to issue start/stop conditions in master
mode. With the clocked synchronous serial format, this bit
has no meaning. With the I
2
C bus format, this bit is set to 1
when the SDA level changes from high to low under the
condition of SCL = high, assuming that the start condition
has been issued. This bit is cleared to 0 when the SDA
level changes from low to high under the condition of SCL
= high, assuming that the stop condition has been issued.
Write 1 to BBSY and 0 to SCP to issue a start condition.
Follow this procedure when also re-transmitting a start
condition. Write 0 in BBSY and 0 in SCP to issue a stop
condition. To issue start/stop conditions, use the MOV
instruction.