6.2 Using Programs in Normal System Configuration
6.2.1 Before creating a program
6
PROGRAMMING
(2) Intelligent function module switch setting
Based on the setting conditions given in Section 6.2 (2), make the intelligent function
module switch setting.
(a) Setting details of each switch
1) Switch 1, Switch 2: Measurement range setting
2) Switch 3 : Offset/gain setting
3) Switch 4: Mode setting
4) Switch 5: Use prohibited (Fixed to 0
H.
*1
)
* 1 If any value other than 0H is set, an error occurs.
(b) Intelligent function module switch setting
Click the button on the "I/O assignment" tab of PLC parameter in GX
Developer to display the following screen, and make settings for switch 1 to 5.
CH4 CH3CH2 CH1
H
0000
CH6 CH5CH8CH7
H
0000
<Switch 2>
<Switch 1>
CH4 to CH8: 0
H (Default value)
CH1 to CH3: 0
H (Pt100 (-200 to 850 ))
H
0000
CH1 to CH3: 0 (Factory default setting)
CH4 to CH8: 0 (Default value)
<Switch 3>
00000000
b7 b6 b5 b4 b3 b2 b1 b0
CH8CH7 CH6CH5CH4 CH3CH2CH1
Fixed
to 0
H
H
Fixed to 0H
All channels: 0H (Normal mode)
0000
<Switch 4>
H
0000
<Switch 5>
Fixed to 0
H
*1