7
ONLINE MODULE CHANGE
7.3 Procedures of Online Module Change
7.3.5 When user range setting is used and initial setting has been made with sequence program (Separate
7 - 25
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
PROCEDURES AND
SETTINGS BEFORE
SYSTEM OPERATION
5
UTILITY PACKAGE
(GX CONFIGURATOR-TI)
6
PROGRAMMING
7
ONLINE MODULE
CHANGE
8
TROUBLESHOOTING
(b) Click the button to enable a module change.
If the following screen appears, the user range setting cannot be saved.
Click the button, and perform the operation in Section 7.3.6 (2)(c)
and later.
(c) After confirming that the "RUN" LED of the module has turned off, disconnect the
connector and remove the module.
POINT
Make sure to remove the module. If the mounting status is confirmed ("Installation
confirmation" is executed) without removing the module, the module will not start
properly and the "RUN" LED will not turn on.