(b) Setting trace conditions
Set trace conditions on the screen opened by clicking the button on the screen
shown in Figure 6.67.
On the Trace condition settings screen, set the following items.
Number of traces ("No. of traces", "After trigger number of times")
Trace point setting ("Trace point setup")
Trigger point setting ("Trigger point setup")
Additional information ("Trace additional informaton")
Auto start setting ("Auto start trace")
1) No. of traces
There are two items need to be set: "No. of times" and "After trigger number of times".
No. of times: Select the number of executions from the start to the end of sampling trace.
After trigger number of times: Select the number of executions from the trigger point to the end of
sampling trace.
Set the numbers for each items within the following setting range.
("After trigger number of times") ("No. of times") (8192)
Figure 6.68 Trace condition settings screen
Figure 6.69 Relationship between two setting items
Trace condition setting
Trace started Trigger point Trace completed
Number of traces
after trigger
Total number of traces