12 - 4
(2) System information
*5: The Universal model QCPU except the Q00UJCPU, Q00UCPU, Q01UCPU, and Q02UCPU.
*6: The relevant modules are as follows:
• The Universal model QCPU whose serial number (first five digits) is "10012" or later.
• Q13UDHCPU, Q26UDHCPU
*8: The Universal model QCPU except the Q00UJCPU.
Table12.3 Special relay
Number Name Meaning Explanation
Set by
(When Set)
Corres-
ponding
ACPU
M9
Corresponding
CPU
SM202 LED OFF command
OFF ON : LED OFF
• When this relay goes from OFF to ON, the LEDs
corresponding to the individual bits at SD202 go off
UNew
Qn(H)
QnPH
QnPRH
QnU
SM203 STOP contact STOP status • Goes ON at STOP status S (Status change) M9042
QCPU
SM204 PAUSE contact PAUSE status • Goes ON at PAUSE status S (Status change) M9041
SM206 PAUSE enable coil
OFF : PAUSE disabled
ON : PAUSE enabled
• PAUSE status is entered if this relay is ON when the
PAUSE contact goes ON
UM9040
SM210 Clock data set request
OFF : Ignored
ON : Set request
• When this relay goes from OFF to ON and after END
instruction execution of subsequent scan, clock data
stored in SD210 to SD213 are written to the CPU
module.
UM9025
SM211 Clock data error
OFF : No error
ON : Error
• ON when error is generated in clock data (SD210 to
SD213) value, and OFF if no error is detected.
S (Request) M9026
SM213
Clock data read
request
OFF : Ignored
ON : Read request
• When this relay is ON, clock data is read to SD210 to
SD213 as BCD values.
UM9028
SM220
CPU No.1 preparation
completed
OFF : CPU No.1 preparation
uncompleted
ON : CPU No.1 preparation
completed
Turned ON when access can be made to the CPU
module No.1 from the other CPU module at power-on
or reset operation. SM220 is used as interlock for
accessing the CPU module No.1 when the multiple
CPU synchronous setting is asynchronous.
S (When status
changed)
New
QnU
SM221
CPU No.2 preparation
completed
OFF : CPU No.2 preparation
uncompleted
ON : CPU No.2 preparation
completed
Turned ON when access can be made to the CPU
module No.2 from the other CPU module at power-on
or reset operation. SM221 is used as interlock for
accessing the CPU module No.2 when the multiple
CPU synchronous setting is asynchronous.
QnU
*8
SM222
CPU No.3 preparation
completed
OFF : CPU No.3 preparation
uncompleted
ON : CPU No.3 preparation
completed
Turned ON when access can be made to the CPU
module No.3 from the other CPU module at power-on
or reset operation. SM222 is used as interlock for
accessing the CPU module No.3 when the multiple
CPU synchronous setting is asynchronous.
SM223
CPU No.4 preparation
completed
OFF : CPU No.4 preparation
uncompleted
ON : CPU No.4 preparation
completed
Turned ON when access can be made to the CPU
module No.4 from the other CPU module at power-on
or reset operation. SM223 is used as interlock for
accessing the CPU module No.4 when the multiple
CPU synchronous setting is asynchronous.
QnU
*5
SM235
Online module change
flag
OFF : Online module change
is not in progress
ON : Online module change
in progress
• Turns on during online module change. (for host
CPU)
S (During online
module change)
New
QnPH
SM236
Online module change
complete flag
OFF : Online module change
incomplete
ON : Online module change
complete
• Turns ON for one scan after online module change is
complete.
• This contact point can only be used by the scan
program. (for host CPU)
S (When online
module change is
complete)
New
SM237
Device range check
inhibit flag
OFF : Device range checked
ON : Device range not
checked
• Selects whether to check a device range during
execution of the BMOV, FMOV or DFMOV
instruction (only when the conditions for subset
processing are established).
UNew
QnU
*6