Mitsubishi Electronics QnUCPU Home Theater Server User Manual


 
8 - 19
CHAPTER8 PARAMETERS
1
2
3
4
5
6
7
8
8.1 PLC Parameters
(14) Built-in Ethernet port Note8.5Note1
Parameters required for use of the built-in Ethernet port are set.
(To the next page)
Note1
Figure 8.14 Built-in Ethernet port
Table8.14 Built-in Ethernet port setting list
Item
Parameter
No.
Description Setting range Default Reference
IP address
1016
H
IP address:
Enter the IP address of the
QnUDE(H)CPU.
Subnet mask pattern:
Enter the subnet mask pattern
when using a router.
Default router IP address:
Enter the IP address of the
router.
IP address:
0.0.0.1 to 223.255.255.254
(00000001
H
to 0DFFFFFFE
H
)
Subnet mask pattern:
Blank or
192.0.0.0 to 255.255.255.252
(0C0000000
H
to 0FFFFFFFC
H
)
Default router IP address:
Blank or
0.0.0.1 to 223.255.255.254
(00000001
H
to 0DFFFFFFE
H
)
IP address:
192.168.3.39
Subnet mask
pattern:
Blank
Default router IP
address:
Blank
QnUCPU
Userís
Manual(Com
munication via
Built-in
Ethernet Port)
Communication
data code
Select the code for MC protocol
communication.
Binary code/ASCII code Binary code
Note8.5
The Universal model QCPUs other than the Built-in Ethernet port QCPU are not equipped with any Ethernet port.
Universal