Mitsubishi Electronics QnUCPU Home Theater Server User Manual


 
12 - 44
*9: Function version is B or later.
Table12.20 Special register
Number Name Meaning Explanation
Set by
(When Set)
Corres-
ponding
ACPU
D9
Corresponding
CPU
SD242
A/Q base
differentiation
Base type
differentiation
0: QA**B is
installed
(A mode)
1: Q**B is installed
(Q mode)
S (Initial) New
Qn(H)
QnPH
QnPRH
Installed Q base
presence/
absence
Base type
differentiation
0: Base not
installed
1: Q**B is installed
S (Initial) New Q00J/Q00/Q01
Installed Q base
presence/
absence
Base type
differentiation
0: Base not
installed
1: Q**B is installed
The bits from the third extension stage to the seventh extension stage
are fixed to "0" in the Q00UJCPU.
The bits from the fifth extension stage to the seventh extension stage are
fixed to "0" in the Q00UCPU, Q01UCPU, and Q02UCPU.
S (Initial) New QnU
SD243
No. of base
slots
No. of base slots
As shown above, each area stores the number of slots being installed.
The bits from the third extension stage to the seventh extension stage
are fixed to "0" in the Q00UJCPU.
The bits from the fifth extension stage to the seventh extension stage are
fixed to "0" in the Q00UCPU, Q01UCPU, and Q02UCPU.
S (Initial) New
Qn(H)
QnPH
QnPRH
QnU
SD244
SD243
No. of base
slots (Operation
status)
No. of base slots
As shown above, each area stores the number of slots being installed.
(Number of set slots when parameter setting has been made)
S (Initial)
New
Q00J/Q00/Q01
SD244
SD245
No. of base
slots (Mounting
status)
No. of base slots
As shown above, each area stores the number of module-mounted slots
of the base unit (actual number of slots of the installed base unit).
S (Initial)
Q00J/Q00/Q01
*9
SD246
SD250
Loaded
maximum I/O
Loaded maximum
I/O No.
When SM250 goes from OFF to ON, the upper 2 digits of the final I/O
number plus 1 of the modules loaded are stored as BIN values.
S (Request
END)
New
Qn(H)
QnPH
QnPRH
The upper 2 digits of the final I/O number plus 1 of the modules loaded
are stored as BIN values.
S (Initial) New
Q00J/Q00/Q01
QnU
b0b1b2b7
to
Fixed to 0
Main base unit
1st extension
base
2nd extension
base
to
7th extension
base
Fixed to 0
when the
base is not
installed.
b0b1b2b4
Fixed to 0
Main base unit
1st extension base
2nd extension base
4th extension base
to
to
b0b1b2b7
to
Fixed to 0
Main base unit
1st extension
base
2nd extension
base
to
7th extension
base
Fixed to 0
when the
base is not
installed.
SD243
SD244
b15 to b12 b11 to b8 b7 to b4 b3 to b0
Extension
3
Extension
2
Main
Extension
1
Extension
7
Extension
6
Extension
4
Extension
5
SD243
SD244
b15 to b12 b11 to b8 b7 to b4 b3 to b0
Extension
3
Extension
2
Main
Extension
1
Fixed to
0
Fixed to
0
Extension
4
Fixed to
0
SD245
SD246
b15 to b12 b11 to b8 b7 to b4 b3 to b0
Extension
3
Extension
2
Main
Extension
1
Fixed to
0
Fixed to
0
Extension
4
Fixed to