Pelco C2669M DVR User Manual


 
94 C1695M (8/06)
MODIFYING THE RELAY OUTPUT NAME
TIP: You can use an optional KBD5000 keyboard or a USB PC keyboard and mouse to perform some setup tasks more easily. Refer to
Understanding DVR5100 Controls and Menus on page 31 for a comparison on using any of these devices to work with the on-screen menus.
To modify the relay output name:
1. If it is not already open, select the Configuration tab for the relay array from the Devices tab on the Setup window. For information about
displaying relay array options, refer to Displaying the Relay Array Options on page 93.
2. Navigate to the Modify Relay Name field, and then use the on-screen keyboard to enter a user-friendly name for the relay device.
3. Select Apply to save your changes and continue working with settings on this page. Select OK to save your changes and close
the page. To retain the original settings, select Cancel . The DVR5100 main application window is displayed.
CONFIGURING THE RELAY MODE
TIP: You can use an optional KBD5000 keyboard or a USB PC keyboard and mouse to perform some setup tasks more easily. Refer to
Understanding DVR5100 Controls and Menus on page 31 for a comparison on using any of these devices to work with the on-screen menus.
To configure a relay or relay array:
1. If it is not already open, select the Configuration tab for the relay array from the Devices tab on the Setup window. For information about
displaying relay array options, refer to Displaying the Relay Array Options on page 93.
2. Navigate to the Mode list, and then select the relay mode from the relay mode that you want to use. Options are Off, On (default), Toggle,
and Pulse.
3. If you are using the pulse mode, modify the following settings:
Navigate to the relay period, and then select a value for the pulse. This setting defines the total time in tenths of a second (5–
1,000) for the relay control pulse (1 second is the default value).
Navigate to the On state field, and then set the percentage of time during the defined period that the relay will be in the ON
state. The default value is 50%.
Set the number of times (0–99) the relay will be pulsed (that is, placed in the ON state) during the defined period. Five is the
default value.
4. Select Apply to save your changes and continue working with settings on this page. Select OK to save your changes and close
the page. To retain the original settings, select Cancel . The DVR5100 main application window is displayed.