GDRVGDEL Gate Delay for the Frequency Window
GDRVGDEL
Gate Delay for the Frequency Window
For the frequency window only, GDRVGDEL sets the time delay from when the gate trigger
occurs to when the gate is opened.
Syntax
\
/
XGDRVGDEL
Item
I
Description/Default
R=u3e
Number
Any real or integer number. Default unit is seconds.
1 ps to 65 ms.
Equivalent Softkey: GDRVGDEL is equivalent to
GATE DELAY
when using the gate utility
(GATE
UTILfTY
)
functions.
Option Required: Option 105. Option 101 is recommended.
Preset Value: 1
ps
Related Commands: GDRVUTIL, GDRVGLEN, GD, GL.
Example
OUTPUT
718;"MOV
GDRVGDEL,lUS;"
Sets the gate
marker
delay
to 1
ps.
Description
If the frequency window is currently the active window, GDRVGDEL updates the gate position
markers and the position of the gate. If the time window is currently active, only the gate
position markers are updated.
You can execute the GDRVGDEL command two different ways. You can either execute the
GDRVGDEL command directly (for example,
"GDRVGDEL
IMS
;
‘I)
or use the MOV command
to move the value for the time delay into the GDRVGDEL command (for example,
“MOV
GDRVGDEL,
1MS
;
‘I).
If you use the MOV command, no text is displayed in the active function
area during command execution.
The GDRVGDEL command is a gate utility function (see “GDRVUTIL” for more information
about the gate utility functions). Executing a gate utility command without Option 105
installed in the spectrum analyzer generates the
COMMAND ERROR:
message and an SRQ 140.
Programming Commands 5-191