Agilent Technologies 8590 TV Converter Box User Manual


 
LIMIMODE Limit-Line Entry Mode
LIMIMODE
Limit-Line Entry Mode
Determines whether the limit-line entries are treated as upper amplitude values, lower
amplitude values, upper and lower amplitude values, or mid-amplitude and delta values.
Syntax
Related Commands: LIMILINE, LIMISEG, LIMISEGT, SEGDEL, SENTER, SENTERT.
Example
This example uses LIMIMODE to enter segments into the upper limit-line table, and then to
enter a segment into the lower limit-line table (upper and lower limit lines are treated as
separate tables). Line 60 demonstrates entering a segment into a combined upper and lower
limit-line table.
10 OUTPUT
718;"LIMIDEL;"
Deletes the current limit-line ta-
ble, sets the table type to
jixed.
Specifies the upper limit-line table.
Selects a limit line based on frequency.
Enters a segment into the up-
per limit-line table.
Because
the
LMSEG
command is used, the
limit-line table will be based on
freq-9.
Spec@.es
the lower limit-line table.
Enters a segment into the lower
limit-line table.
20 OUTPUT
718;"LIMIMODE
UPPER;"
30 OUTPUT
718;"LIMIFT
FREQ;"
40 OUTPUT
718;"LIMISEG
300MHZ,-30DB,SLOPE;"
50 OUTPUT
718;"LIMIMODE
LOWER;"
60 OUTPUT
718;"LIMISEG
300MHZ,-70DB,SLOPE;"
70 OUTPUT
718;"LIMIMODE
UPLOW;"
80 OUTPUT
718;"SENTER
350MHZ,-30DB,-80DB,FLAT;"
90 OUTPUT
718;"LIMIDISP
ON;"
100
END
SpecQies
the upper and lower
limit-
line tables.
Enters a segment into the upper
and
lower
limit-line tables.
Displays the limit lines.
Programming Commands 5-281