Agilent Technologies 8590 TV Converter Box User Manual


 
completed. See the description for INVALID CARD above for more information about the
possible causes of this message. (U) and (H)
INVALID CARD: DATA ERROR
Indicates the data could not be retrieved from the memory card. (U) and (H)
INVALID CARD:
DIRECI?ORY
Indicates the memory card has not been formatted. (U)
INVALID CARD: NO CARD
Indicates a memory card has not been inserted. (U)
INVALID CARD: TYPE
Indicates one of the following conditions: a card reader is not installed, the memory card is
write-protected (check the position of the switch on the memory card), the memory card is a
read-only memory (ROM) card, or a memory card has not been inserted. This message can
also occur if remote programming commands for the memory card capability are executed
with an HP
85901,
or HP 8592L that does not have an Option 003. (U)
INVALID CHECKSUM: USTATE
The user-defined state does not follow the expected format. (U)
INVALID COMPARE OPERATOR
An IF/THEN or REPEAT/UNTIL routine is improperly constructed. Specifically, the IF or
UNTIL operands are incorrect. (U)
INVALID DET: FM or TV option only
Indicates that the selected detector cannot be used until the appropriate option is installed in
the spectrum analyzer. (U)
INVALID ENTER FORMAT
The enter format is not valid. See the appropriate programming command description to
determine the correct format. (U)
INVALID
<file
name> NOT FOUND
Indicates that the specified file could not be loaded into spectrum analyzer memory or
purged from memory because the file name cannot be found. (U)
INVALID FILENAME
_
_
_
Indicates the specified file name is invalid. A file name is invalid if there is no file name
specified, if the first letter of the file name is not alphabetic, or if the specified file type does
not match the type of file. See the description SAVRCLW or STOR programming command for
more information. (U)
INVALID FILE: NO ROOM
Indicates that there is insufficient space available on the memory card to store the data. (U)
INVALID BP-IB
ADRWOPERATION
An HP-IB operation was aborted due to an incorrect address or invalid operation. Check that
there is only one controller (the spectrum analyzer) connected to the printer or plotter. (U)
INVALID BP-IB OPERATION REN TRUE
The HP-IB operation is not allowed. (This is usually caused by trying to print or plot when a
controller is on the interface bus with the spectrum analyzer.)
lb
use the spectrum analyzer
print or plot functions, you must disconnect any other controllers on the HP-IB. If you are
using programming commands to print or plot, you can use an HP BASIC command instead
of disconnecting the controller. See the description for the PRINT command for more
information. (U)
INVALID ITEM:-
-
_
Indicates an invalid parameter has been used in a programming command. (U)