Avaya G700 Home Theater Server User Manual


 
Install the S8300
Issue 9.1 June 2006 475
Software and firmware update reminder
When the installation is complete, the CD drive door opens and the system reboots
automatically. The reboot takes 1–3 minutes without the IA770 application, and much longer if
the IA770 is present.
In the event you used the laptop TFTP server and you have a problem with power and the
S8300 does not reboot, there are two methods of recovery:
Use the USB CD-ROM to plug into the S8300 and repeat the remastering process using
the Unity CD.
Arrange access to another hard drive (comcode 700307028) should it be necessary to
perform the TFTP remaster procedure on it.
Verifying Software Version
Note:
Note: Since the system is now running a new software release, you must login with the
initial craft ID and password. (You cannot use dadmin at this point.)
To verify the software version:
1. Log on to Integrated Management and launch the Maintenance Web Interface.
2. Under Server, click Software Version.
3. Verify that the media server is running Release 3.0 software.
The Report as: string should show R012x.01 at the beginning of the string. For example,
R012x.01.0.411.1.
Tip:
Tip: Normally, you would need to use the Make Upgrade Permanent function on the
Web Interface at this point. However, this is not necessary for this upgrade
because there is no previous software version in the alternate partition.