Emerson HASXEE-IM-HS TV Video Accessories User Manual


 
Emerson Process Management GmbH & Co. OHG 1-1
X-STREAM XE
Instruction Manual
HASXEE-IM-HS
04/2010
Chapter 1
Technical Description
The following are the main features of the new
Emerson Process Management X-STREAM
gas analyzers in brief:
compact design with easily accessible
internal components
customizable for a wide range of appli-
cations: different housings are available
while internal construction remains largely
identical
a highly integrated mainboard contains
all interfaces and basic functions for the
operation of the unit
multilingual microprocessor-controlled
user interface with liquid crystal (LCD) to
indicate measurement value and status
messages
units for outdoor use are optionally sup-
plied with an impact tested front panel
widerange power supply unit for worldwide
use without modication (
1
2 19in units with
external PSUs)
The new X-STREAM gas analyzers can
measure up to ve different gas compon-
ents using any combination of the following
analyzing techniques (restrictions apply to
1
2 19in units):
IR = non-dispersive infrared analysis
UV = ultraviolet analysis
pO
2
=
paramagnetic oxygen analysis
eO
2
=
electrochemical oxygen analysis
TC = thermal conductivity analysis
Modied resistant measuring cells are avai-
lable for use with corrosive gases and/or
gases containing solvents.
Special congurations (e.g. intrinsically safe
or infallible measuring cells) for the analysis
of combustible gases are also available.
Chapter 3 gives a detailed description of
the various measuring techniques.
Standard applications
Different housings allow X-STREAM ana-
lyzers to be tailored to the many different
applications:
Tabletop units in
1
2 19in modular design,
with IP 20 protection class
Tabletop and rack mountable units in 19in
modular design, with IP 20 protection
class
Stainless steel wall mountable field
housing with IP 66 / NEMA 4X protection
class for outdoor use (operating tempera-
ture -20°C to +50°C).
Cast aluminium wall mountable field
housing with IP 66 / NEMA 4X protection
class for outdoor use (operating tempera-
ture -20 °C to +50 °C).
The various analyzer types are described in
more detail beginning with 1-13.
Installation in hazardous areas
X-STREAM analyzers in eld housings, when
tted with various protective devices, can also
be installed and operated in hazardous areas.
Available options are:
Pressurized enclosure conforming to
ATEX directive 94/9/EC, for installation
in Zone 2.
1
Technical Description