Emerson HASXEE-IM-HS TV Video Accessories User Manual


 
Emerson Process Management GmbH & Co. OHG 2-5
X-STREAM XE
Instruction Manual
HASXEE-IM-HS
04/2010
2
Technical Data
2.1 Common Technical Data
Optional interfaces for all models
Analog I/O board
2 analog inputs
electrical
specication
0 - 1 V, 0 - 10 V (software selectable)
R
in
= 100 kΩ
optional (requires to t wire bridges,
Chapter 4 'Installation'):
4 (0) - 20 mA ; R
in
= 50Ω
optically isolated from analyzer GND
protected against overload up to
±15 V
or
±20 mA
function
Input analog signals from external de-
vices, such as e.g.
pressure transmitters,
ow sensors,
analyzers, etc.
for compensation or other purposes
Serial Interface
1 Interface
electrical
specication
9-pin,optically isolated from analyzer
electronics
function RS232C, RS485 or Modbus
Special Interface
Service Interface
1 serial
electrical
specication
RS232C,
NOT optically isolated from analyzer electronics
function Only for special trained service personnel!