Modbus Commands
9.4 List of Parameters and Registers - Sorted by Daniel Registers
Address
Tag Name
Data
Type
Client
Access
Description
Daniel Modicon
3404 3404
Service.Measurement.Compensati-
on.ToffEnable4
Word R/W enable temperature zero compensation of comp4
3405 3405
Service.Measurement.Compensati-
on.ToffEnable5
Word R/W enable temperature zero compensation of comp5
3406 3406
Service.Measurement.Compensati-
on.ToffSensorAssign1
Word R/W
assign temp-sensor of zero comp1 (0=None,
1=DSP_T1, 2=DSP_T2 etc.)
3407 3407
Service.Measurement.Compensati-
on.ToffSensorAssign2
Word R/W
assign temp-sensor of zero comp2 (0=None,
1=DSP_T1, 2=DSP_T2 etc.)
3408 3408
Service.Measurement.Compensati-
on.ToffSensorAssign3
Word R/W
assign temp-sensor of zero comp3 (0=None,
1=DSP_T1, 2=DSP_T2 etc.)
3409 3409
Service.Measurement.Compensati-
on.ToffSensorAssign4
Word R/W
assign temp-sensor of zero comp4 (0=None,
1=DSP_T1, 2=DSP_T2 etc.)
3410 3410
Service.Measurement.Compensati-
on.ToffSensorAssign5
Word R/W
assign temp-sensor of zero comp5 (0=None,
1=DSP_T1, 2=DSP_T2 etc.)
3411 3411
Service.Measurement.Compensati-
on.TfactEnable1
Word R/W enable temperature span compensation of comp1
3412 3412
Service.Measurement.Compensati-
on.TfactEnable2
Word R/W enable temperature span compensation of comp2
3413 3413
Service.Measurement.Compensati-
on.TfactEnable3
Word R/W enable temperature span compensation of comp3
3414 3414
Service.Measurement.Compensati-
on.TfactEnable4
Word R/W enable temperature span compensation of comp4
3415 3415
Service.Measurement.Compensati-
on.TfactEnable5
Word R/W enable temperature span compensation of comp5
3416 3416
Service.Measurement.Compensati-
on.TfactSensorAssign1
Word R/W
assign temp-sensor of span comp1 (0=None,
1=DSP_T1, 2=DSP_T2 etc.)
3417 3417
Service.Measurement.Compensati-
on.TfactSensorAssign2
Word R/W
assign temp-sensor of span comp2 (0=None,
1=DSP_T1, 2=DSP_T2 etc.)
3418 3418
Service.Measurement.Compensati-
on.TfactSensorAssign3
Word
R/W
assign temp-sensor of span comp3 (0=None,
1=DSP_T1, 2=DSP_T2 etc.)
3419 3419
Service.Measurement.Compensati-
on.TfactSensorAssign4
Word R/W
assign temp-sensor of span comp4 (0=None,
1=DSP_T1, 2=DSP_T2 etc.)
3420 3420
Service.Measurement.Compensati-
on.TfactSensorAssign5
Word R/W
assign temp-sensor of span comp5 (0=None,
1=DSP_T1, 2=DSP_T2 etc.)
3421 3421
Service.Measurement.Compensati-
on.PfactEnable1
Word R/W enable pressure span compensation of comp1
3422 3422
Service.Measurement.Compensati-
on.PfactEnable2
Word R/W enable pressure span compensation of comp2
3423 3423
Service.Measurement.Compensati-
on.PfactEnable3
Word R/W enable pressure span compensation of comp3
3424 3424
Service.Measurement.Compensati-
on.PfactEnable4
Word R/W enable pressure span compensation of comp4
3425 3425
Service.Measurement.Compensati-
on.PfactEnable5
Word R/W enable pressure span compensation of comp5
3426 3426
Service.Measurement.Compensati-
on.PfactSensorAssign1
Word R/W
assign press-sensor of span comp1 (0=Man,
1=DSP_P1, 2=DSP_P2 etc.)
3427 3427
Service.Measurement.Compensati-
on.PfactSensorAssign2
Word R/W
assign press-sensor of span comp2 (0=Man,