Emerson HASXEE-IM-HS TV Video Accessories User Manual


 
Emerson Process Management GmbH & Co. OHG 9-3
X-STREAM XE
Instruction Manual
HASXEE-IM-HS
04/2010
9
Modbus Commands
9.3 List of Parameters and Registers - Sorted by Tag Name
Tag Name Address
Data
Type
Client
Access
Description
Modicon Daniel
Control.Acknowledge.AllStates 2091 2091 Boolean R/W
0=no effect, 1=Acknowledge device‘s
states
Control.Acknowledge.Failure 2092 2092 Boolean R/W
0=no effect, 1=Acknowledge device‘s
Namur Failure alarms
Control.Acknowledge.FctChecks 2095 2095 Boolean R/W
0=no effect, 1=Acknowledge device‘s
Namur FctCheck alarms
Control.Acknowledge.LevelAlarms 2096 2096 Boolean R/W
0=no effect, 1=Acknowledge device‘s
level alarms
Control.Acknowledge.MaintRequests 2094 2094 Boolean R/W
0=no effect, 1=Acknowledge device‘s
Namur MaintRequ alarms
Control.Acknowledge.OffSpecs 2093 2093 Boolean R/W
0=no effect, 1=Acknowledge device‘s
Namur Off-spec alarms
Control.ApplyGas.PumpState1 2081 2081 Boolean R/W Pump1 state (0=Off, 1=On)
Control.ApplyGas.PumpState2 2082 2082 Boolean R/W Pump1 state (0=Off, 1=On)
Control.ApplyGas.SampleValve1 2051 2051 Boolean R/W
0=close all valves, 1=open sample
valve comp1
Control.ApplyGas.SampleValve2 2052 2052 Boolean R/W
0=close all valves, 1=open sample
valve comp2
Control.ApplyGas.SampleValve3 2053 2053 Boolean R/W
0=close all valves, 1=open sample
valve comp3
Control.ApplyGas.SampleValve4 2054 2054 Boolean R/W
0=close all valves, 1=open sample
valve comp4
Control.ApplyGas.SampleValve5 2055 2055 Boolean R/W
0=close all valves, 1=open sample
valve comp5
Control.ApplyGas.Span1Valve1 2061 2061 Boolean R/W
0=open sample valve, 1=open span1
valve comp1
Control.ApplyGas.Span1Valve2 2065 2065 Boolean R/W
0=open sample valve, 1=open span1
valve comp2
Control.ApplyGas.Span1Valve3 2069 2069 Boolean R/W
0=open sample valve, 1=open span1
valve comp3
Control.ApplyGas.Span1Valve4 2073 2073 Boolean R/W
0=open sample valve, 1=open span1
valve comp4
Control.ApplyGas.Span1Valve5 2077 2077 Boolean R/W
0=open sample valve, 1=open span1
valve comp5
Control.ApplyGas.Span2Valve1
2062 2062 Boolean R/W
0=open sample valve, 1=open span2
valve comp1
Control.ApplyGas.Span2Valve2 2066 2066 Boolean R/W
0=open sample valve, 1=open span2
valve comp2
Control.ApplyGas.Span2Valve3 2070 2070 Boolean R/W
0=open sample valve, 1=open span2
valve comp3
Control.ApplyGas.Span2Valve4 2074 2074 Boolean R/W
0=open sample valve, 1=open span2
valve comp4
Control.ApplyGas.Span2Valve5 2078 2078 Boolean R/W
0=open sample valve, 1=open span2
valve comp5
Control.ApplyGas.Span3Valve1 2063 2063 Boolean R/W
0=open sample valve, 1=open span3
valve comp1