Emerson HASXEE-IM-HS TV Video Accessories User Manual


 
Emerson Process Management GmbH & Co. OHG A-15
X-STREAM XE
Instruction Manual
HASXEE-IM-HS
04/2010
A
Appendix
A.3 CSA Certicate of Compliance
Certificate:
1714037(LR105173)
Master Contract:
185562
Project:
2247530
Date Issued:
2010/01/21
DQD507Rev.2009-09-01
X-STREAM Gas Analyzer Core (X2CA)TableToporRackMountwithapplianceinletforindooruseand
nodisplay(optionalwithfieldwiringterminalsforindooruse);
Gasanalyzer,Model:X-STREAM,rated100-240Vac,50/60Hz,5.5-3A,ClassI,PollutionDegreeII.
X-STREAM (XXF) or X-STREAM Enhanced Field Housing Gas Analyzer (XDF):Wallmountingwith
fieldwiringterminals,foroutdooruseNEMA4Xanddisplay;
Gasanalyzer,Model:X-STREAM,rated24Vdc,2.5A,ClassI,PollutionDegreeII.
X-STREAM (X2GC)or X-STREAM Enhanced (XEGC)General Purpose Compact Gas Analyzer Table
ToporRackMountwith24Vdcinconnectoranddisplay;
X-STREAM Compact Gas Analyzer Core (X2CC): TableToporRackMountwith24Vdcin
Conditions of Acceptability
-FortheX-STREAMModelsXGP,XGPS,X2GP,X2CAandXEGPtheequipmentissuppliedwithan
approvedpowersupplycordsetorpowersupplycordwithplugthatisacceptabletotheauthoritiesinthe
countrywheretheequipmentistobeused.Unitssuppliedwithoutapowercordandthatarenotpermanently
connectedareconsideredascomponent.Component-typeunitsmustbeprovidedwithaFire,Mechanicaland
Electricalenclosureandmustbere-evaluatedbyCSA.
-Theplug/connectorisusedasthedisconnecteddevice.TheswitchforX2GP/X2CA/XEGPisnotconsidered
thedisconnectdevice.Allunitsmustbeprovidedwithadisconnectdevice.
CLASS 2258-02 PROCESS CONTROL EQUIPMENT – For Hazardous Locations
CLASS 2258-82 PROCESS CONTROL EQUIPMENT – For Hazardous Locations – Certified to U.S.
Standards.
X-Stream FD (XFD):FlameproofforHazardousLocations
ClassI,Zone1,ExdIIB+H2,T3
ClassI,Zone1,AExdIIB+H2,T3
Gasanalyzer,Model:X-Stream,rated100-240Vac,50/60Hz,2–1A.ClassI,PollutionDegreeII;Type4&
IP66
AmbientTemperatureRange:-30°Cto+50°CMaximuminternalcasepressure=110kpa
XFD-abcdefghijklmnop
a=Language:A,B,C,DorE
b=AmbientConditions:1,2,3,4,5or6
c=Instrument:1,2,3,4,5,6or7
d=Bench1:anycombinationof2or3alpha-numericcharacters