Honeywell VRX180 DVR User Manual


 
Programming Function Blocks and Features
Video Recorder – User Manual 112
Table 4-20 Compare’s Condition Type and Condition Time Prompts (continued)
Condition type Application If this is true then CVn OS is
PULSE Used for interfacing with slower
circuits.
On rising edge of Result,
creates pulse length
CONDITION TIME and ignores
additional rising edges of Result
within that CONDITION TIME.
Result switches ON(1) for
CONDITION TIME, then
OFF(0).
ON(1) for CONDITION TIME,
then OFF(0). During
CONDITION TIME, any
additional OFF(0)-to-ONs of
Result are ignored.
3 sec
Condition Type = Pulse
Condition Time = 3 seconds
3 sec
2 sec
If Result is:
Then CVn OS is:
3 sec
3.5 sec
Time
Condition type Application If this is true then CVn OS is
RT PULSE
(Re-triggerable pulse)
Used for slower circuits.
Result switches ON(1) for
CONDITION TIME, then
OFF(0)
ON(1) for CONDITION
TIME, then OFF(0).
Guarantees that CVn OS will be
ON for CONDITION TIME after
most recent rising edge of
Result.
Result switches ON(1) multiple
times before CONDITION TIME
expires
ON(1) when Result first
switches ON(1) and
remains ON(1) until Result
has not switched ON(1) for
CONDITION TIME.
Result switches ON(1) for
CONDITION TIME, then
OFF(0)
ON(1) for CONDITION
TIME then OFF(0).
3 sec
If Result is:
Then CVn OS is:
Time
Pulse is
re-triggered
4 sec
Condition Type = Re-triggerable Pulse
Condition Time = 3 seconds