Honeywell VRX180 DVR User Manual


 
Introduction
Video recorder – User Manual 12
Model Selection Guide (cont.)
VRX180
TABLE V - OPTIONS (continued)
Selection
Approvals CE Mark Compliant _ _ _ 0 _ _
CSA/NRTLc/CE Mark
_ _ _ C _ _
Software None _ _ _ _ 0 _
SDA and SCF _ _ _ _ B _
SCF (Configuration Software) _ _ _ _ C _
SDA
(
Data Anal
y
sis Software
)
_ _ _ _ E _
Case Galvanized Case, Grey Door, Glass Window, Latch _ _ _ _ _ 0
Galvanized Case, Grey Door, Glass Window, Key Lock _ _ _ _ _ 1
Galvanized Case, Grey Door, Plastic Window, Latch _ _ _ _ _ 2
Galvanized Case, Grey Door, Plastic Window, Key Lock _ _ _ _ _ 3
Portable Case (Painted Case, Handles)
_ _ _ _ _ 6
TABLE VI
Factory Use Only 00
SOFTWARES AND SUPPORT PARTS Part #
SDA Data Analysis Software (can be ordered separately if not selected in Table V) 045501
SCF Configuration Software (can be ordered separately if not selected in Table V) 045502
SDI Disk Initialization Software
(Note 6)
46193351-501
Kit of 4 resistors 250 Ohms for 4-20 mA in
p
ut 46181080-503
RESTRICTIONS
Restriction Letter Available With Not Available With
Table Selection Table Selection
c
II
_ _ _ _ _ A, _ _ _ _ _ B, _ _ _ _ _ C,
_ _ _ _ _ E, _ _ _ _ _ R, _ _ _ _ _ G,
_ _ _ _ _ H, _ _ _ _ _ M
Notes:
1. The available algorithms include: PID (standard and advance), Cascade, Split Output and On/Off.
The appropriate outputs from Table I must be specified - Current or Relays.
If Split (Duplex) output Control is required, advance math must be selected ( Table III ).
2. Standard Math includes 24 Calculated Values and the following pre-packaged algorithms
Free Form Math Logic Operators Flip-Flop/One Shot Periodic Timer
Free Form Logic Math Operators Invertor
Advance Math includes 64 Calculated Values and the followin
g
additional of
p
re-
p
acka
g
e al
g
orithms.
Signal Select Interval Timer Counter
Compare Relative Humidity Scaling
Signal Clamp Mass Flow Advanced Splitter
Peak Picking Fo Calculation Continuous Emissions Monitoring
Function Generator Multi
p
le In
p
ut Avera
g
e - CEM Block Average
Carbon Potential Single Point Average - CEM Rolling Average
Rolling Average Standard Splitter
3. Customer must supply Input Actuation Type and Range for each input for inclusion in the free form
section of the Factor
y
order to su
pp
l
y
the Custom Calibration Certificate, otherwise the calibration will be
based on the factory default ranges.
4. When selectin
g
SP
p
ro
g
ram make sure to select analo
g
out
p
ut
(
current
)
as necessar
y
(
Table II slot N,P
)
.
5. When selecting Control loops, make sure to select outputs (as necessary in Table II)
6. Provided with each VRX180 are : one pre-initialized disk and one SDI software pack.
SDI software should be installed on a PC and used for initialization of new disks.
7. Must purchase Table II _ _ _ _ M _ in order to select Table II Selection _ _ _ _ _ M.