Honeywell VRX180 DVR User Manual


 
Introduction
Video Recorder - User Manual 9
Table 1-4 Standards
This product is designed and manufactured to be in conformity with applicable U.S., Canadian, and International
(IEC/CENELEC/CE) standards for intended instrument locations. The following Standards and Specifications are
met or exceeded.
Case Protection IP55 on front door only, when the instrument is panel mounted and the front door
securely closed.
Rear of Panel EN 60529, IP 20
Flammability Rating UL 94 - V2
Vibration Level 10 to 40 Hz, 0.07 mm displacement; 40 to 60 Hz, 0.2g acceleration
Electromagnetic
Compatibility
CE EMC Directive 89/336/EEC
Safety IEC1010 Installation Category II for personal protection
Intended Instrument
Locations
Rack or panel mounting in control room or industrial environments (operator
accessibility front of panel only)
Installation Category II with grounded mains supply from isolation transformer or GFI
(ground fault interrupter)
Pollution Degree 2 with rear of panel enclosed, in industrial environment